Using the dishwasher
ALARM TEXT
(0)
PLATFORM ERROR
(63) POWER SUPPLY
FAILURE
CHECK THE
EMERGENCY SWITCH
(98) HARDWARE ERROR
POWER ON FUNCTION
DEFECT
CALL SERVICE
(3)
NOMINAL VALUES
CORRUPTED IN MEMORY
CALL SERVICE
(99)
THE MACHINE TYPE
HAS BEEN CHANGED
VERIFY THIS
(2)
INPUT FAILURE ON
DIGITAL INPUTS
CALL SERVICE
(100)
NOMINAL VALUES
RESTORED FROM UI
(4) COMMUNICATION ERR
BETWEEN CPU BOARD
AND I/O BOARD1
CALL SERVICE
(7) COMMUNICATION ERR
BETWEEN CPU BOARD
AND U/I BOARD
CALL SERVICE
(9)
OVERLOAD PUMPS
ACTIVATED
CALL SERVICE
(10) HACCP ALARM
PUMP FUNCTIONALITY
DEFECT
PRESS RESET
(11) HACCP ALARM
PUMP DEFECT
MACHINE LOCKED
CALL SERVICE
(20)
FREQUENCY INVERTER
ERROR
CALL SERVICE
(16)
COMMUNICATION ERROR
FREQUENCY INVERTER
CALL SERVICE
WD-90 DUO
ACTION
Switch off the machine and restart it.
Switch off the machine and restart it.
Switch off the machine and restart it.
Contact service personnel.
This alarm should not occur on normal operation. If it does, contact service per-
sonnel.
Contact service personnel.
This is an information text.
Reset with the reset button on the machine.
Restart the machine.
Restart the machine.
Contact service personnel.
Reset the alarm by pressing the reset button.
In certain cases, the machine may lock when this alarm is displayed. If this hap-
pens, contact service personnel.
The machine is locked when this alarm is activated. Contact service personnel.
Contact service personnel if the alarm cannot be reset or if it recurs.
Contact service personnel if the alarm cannot be reset or if it recurs.