7.3 Alarm Function Configuration Example

Configuration Description
As shown in
R1.

Figure 7-1 Alarm Function Configuration Example

Configuration Flow
1. Enable the alarm function.
2. Configure alarm levels, levels of alarms printed on a terminal, alarm buffer, alarm
clearing mode when the buffer is full, interval for writing logs, time display mode, and
address of the server to which alarms are sent.
3. Configure alarm Trap, Trap type and address of the server to which Trap messages
are sent.
Configuration Commands
Run the following commands on R1:
R1(config)#logging on
R1(config)#logging level warnings
R1(config)#logging console warnings
R1(config)#logging buffer 200
R1(config)#logging mode fullcycle
R1(config)#logging cmdlog-interval 2880
R1(config)#logging ftp warnings 192.168.154.253 zte zte ztelog
R1(config)#logging timestamps datetime localtime
R1(config)#logging Trap-enable notifications
R1(config)#snmp-server enable Trap
R1(config)#snmp-server version v2c enable
R1(config)#snmp-server host 192.168.154.253 Trap version 2c zte
SJ-20140504150128-007|2014-05-10 (R1.0)
show logging alarm type-id power
Figure
7-1, a PC is connected to R1. Users can view alarm information on
Chapter 7 Alarm Management Configuration
Function
Displays power alarms.