Dynacode series
Replacing pneumatic
valve and pressure
control device
Figure 23
Figure 24
0808

5.7 Replacing parties at print mechanics

DANGER!
Risk of injury via a short-circuit.
Because of technical reasons, the adjusting screw of
pressure control device unit is on a tension potential of 5V.
Use isolated tools.
Do not touch components connected with mass.
At the new pressure control device you have to set the
switch-point. For this procedure, the compressed air supply is
set to 2 bars at manometer. In the 'Service Functions' menu
the value 'P' for compressed-air control is examined. Turn at
the adjusting thread of pressure control device (between flat
connections!) until the value changes from 0 to 1.
If you set at manometer a value smaller 2 bar, then value 'P'
must be again set to 0. Adjust finely again if necessary.
Service instructions
1. Remove rear-mounted
mechanics cover after
loosening the collateral screw.
2. Unscrew screws (A, C and G).
3. Loosen piece of tube (E) from
plug-in connection of valve (B)
and remove pressure control
device unit (H) outwards.
4. Loosen piece of tube (diameter
4 mm) at the bottom side of
valve (not visible) and remove
valve.
5. Remove valve from aluminium
fastener by loosing screw (D).
6. At a defective pressure control
device you have to remove the
screw in union (F) including
seals and the flat connection (I)
7. The installation of all
components is to be effected in
reverse order.