Carl Valentin Dynacode Series Service Instructions Manual page 36

Thermal transfer direct printing systems
Table of Contents

Advertisement

Error correction
Error message
46
Drive write-
protected
47
Directory not file
48
File already open
49
No file/directory
50
Invalid file name
51
Internal file error
52
Root full
53
Drive full
54
File/directory
exists
55
File too large
56
No update file
57
Invalid graphic file
58
Directory not empty
59
No interface
60
No CF card
61
Webserver error
62
Wrong FPGA
63
End position
36
Cause
Memory card is write-protected.
Attempt to indicate a directory
as file name.
Attempt to change a file during
an access is active.
File does not exist on CF card.
File name contains invalid
characters.
Internal file system error.
The max. number (64) of main
directory entries is reached.
Maximum CF capacity is
reached.
The selected file/directory
already exists.
During copying procedure not
enough memory space onto
target drive available.
Errors in update file of
firmware.
The selected file does not
contain graphic data.
Attempt to delete a not empty
directory.
No CF card drive found.
No CF card is inserted.
Error at start of web server.
The direct print module is
equipped with the wrong
FPGA.
The label length is too long.
The number of labels per cycle
is too much.
Service instructions
Dynacode series
Remedy
Deactivate write protection.
Correct your entry.
Select another file.
Check file name.
Correct entry of name, remove
special characters.
Please contact your distributor.
Delete at least one main
directory entry and create
subdirectories.
Use new CF Card, delete no
longer required files.
Check name, select a different
name.
Use a larger target card.
Start update file anew.
Check file name.
Delete all files and sub-
directories in the desired
directory.
Check connection of CF card
drive.
Contact your distributor
Insert CF card in the slot.
Please contact your distributor.
Please contact your distributor.
Check label length res. the
number of labels per cycle.
0808