Pid Control Parameters; Communication Parameter - gefran ADV20 series Quick Start-Up

Compact v/f ac drive 0.4 to 3.7 kw 115-230 vac 1ph, 230-460 vac 3ph
Table of Contents

Advertisement

Available languages

Available languages

Parameter
Explanation
08.17
Auto Energy Saving
08.18
AVR Function
08.19
Reserved
Compensation
08.20
Coefficient for Motor
Instability
Communication
09.00
Address
09.01
Transmission Speed
Transmission Fault
09.02
Treatment
09.03
Time-out Detection
Communication
09.04
Protocol
09.05
Reserved
09.06
Reserved
Response Delay
09.07
Time
PID Set Point
10.00
Selection
20
ADV20 QS, V1.02
0: Disable
1: Enable
0: AVR function enable
1: AVR function disable
2: AVR function disable for decel.
3: AVR function disable for stop
0.0~5.0
Group 9 Communication Parameters
1 to 254
0: Baud rate 4800bps
1: Baud rate 9600bps
2: Baud rate 19200bps
3: Baud rate 38400bps
0: Warn and keep operating
1: Warn and ramp to stop
2: Warn and coast to stop
3: No warning and keep operating
0.1 ~ 120.0 seconds
0.0: Disable
0: 7,N,2 (Modbus, ASCII)
1: 7,E,1 (Modbus, ASCII)
2: 7,O,1 (Modbus, ASCII)
3: 8,N,2 (Modbus, RTU)
4: 8,E,1 (Modbus, RTU)
5: 8,O,1 (Modbus, RTU)
6: 8,N,1 (Modbus, RTU)
7: 8,E,2 (Modbus, RTU)
8: 8,O,2 (Modbus, RTU)
9: 7,N,1 (Modbus, ASCII)
10: 7,E,2 (Modbus, ASCII)
11: 7,O,2 (Modbus, ASCII)
0 ~ 200 (unit: 2ms)
Group 10 PID Control Parameters
0: Disable PID operation
1: Keypad (based on Pr.02.00)
2: 0 to +10V from AVI
3: 4 to 20mA from ACI
4: PID set point (Pr.10.11)
Settings
Italiano
Factory
NOTE
Setting
0
0
0.0
1
1
3
0.0
0
0
1
0
English