Parameter
Explanation
Third Most Recent
06.10
Fault Record
06.11
Fourth Most Recent
Fault Record
Fifth Most Recent
06.12
Fault Record
Motor Rated Current 30 %FLA to 120% FLA
07.00
Motor No-Load
07.01
Current
Torque
07.02
Compensation
07.03
Slip Compensation
(Used without PG)
07.04
|
Reserved
07.09
Accumulative Motor
07.10
Operation Time
(Min.)
Accumulative Motor
07.11
Operation Time
(Day)
Motor PTC
07.12
Overheat Protection
Input Debouncing
07.13
Time of the PTC
Protection
Motor PTC
07.14
Overheat Protection
Level
18
ADV20 QS, V1.02
Settings
during steady state operation (ocn)
12: Ground fault (GFF)
13: Reserved
14: Phase-Loss (PHL)
15: Reserved
16: Auto Acel/Decel failure (CFA)
17: SW/Password protection (codE)
18: Power Board CPU WRITE failure (cF1.0)
19: Power Board CPU READ failure (cF2.0)
20: CC, OC Hardware protection failure
(HPF1)
21: OV Hardware protection failure (HPF2)
22: GFF Hardware protection failure (HPF3)
23: OC Hardware protection failure (HPF4)
24: U-phase error (cF3.0)
25: V-phase error (cF3.1)
26: W-phase error (cF3.2)
27: DCBUS error (cF3.3)
28: IGBT Overheat (cF3.4)
29: Reserved
30: Reserved
31: Reserved
32: ACI signal error (AErr)
33: Reserved
34: Motor PTC overheat protection (PtC1)
35-40: Reserved
Group 7 Motor Parameters
0%FLA to 99% FLA
0.0 to 10.0
0.00 to 10.00
0 to 1439 Min.
0 to 65535 Day
0: Disable
1: Enable
0~9999(*2ms)
0.1~10.0V
Factory
Setting
FLA
0.4*FLA
0.0
0.00
0
0
0
100
2.4