Operation Method Parameters; Basic Parameters - gefran ADV20 series Quick Start-Up

Compact v/f ac drive 0.4 to 3.7 kw 115-230 vac 1ph, 230-460 vac 3ph
Table of Contents

Advertisement

Available languages

Available languages

Parameter
Explanation
Position of Decimal
00.14
Point of User-
defined Value 1
Maximum Output
01.00
Frequency (Fmax)
Maximum Voltage
01.01
Frequency (Fbase)
Maximum Output
01.02
Voltage (Vmax)
Mid-Point Frequency
01.03
(Fmid)
Mid-Point Voltage
01.04
(Vmid)
Minimum Output
01.05
Frequency (Fmin)
Minimum Output
01.06
Voltage (Vmin)
Output Frequency
01.07
Upper Limit
Output Frequency
01.08
Lower Limit
Accel Time 1
01.09
Decel Time 1
01.10
Accel Time 2
01.11
Decel Time 2
01.12
Jog Acceleration
01.13
Time
Jog Deceleration
01.14
Time
Jog Frequency
01.15
Auto acceleration /
deceleration (refer
01.16
to Accel/Decel time
setting)
Acceleration S-
01.17
Curve
Deceleration S-
01.18
Curve
Accel/Decel Time
01.19
Unit
Source of First
02.00
Master Frequency
Command
Italiano
0 to 3
Group 1 Basic Parameters
50.00 to 600.0 Hz
0.10 to 600.0 Hz
115V/230V series: 0.1V to 255.0V
460V series: 0.1V to 510.0V
0.10 to 600.0 Hz
115V/230V series: 0.1V to 255.0V
460V series: 0.1V to 510.0V
0.10 to 600.0 Hz
115V/230V series: 0.1V to 255.0V
460V series: 0.1V to 510.0V
0.1 to 120.0%
0.0 to100.0 %
0.1 to 600.0 / 0.01 to 600.0 sec
0.1 to 600.0 / 0.01 to 600.0 sec
0.1 to 600.0 / 0.01 to 600.0 sec
0.1 to 600.0 / 0.01 to 600.0 sec
0.1 to 600.0 / 0.01 to 600.0 sec
0.1 to 600.0 / 0.01 to 600.0 sec
0.10 Hz to Fmax (Pr.01.00) Hz
0: Linear Accel/Decel
1: Auto Accel, Linear Decel
2: Linear Accel, Auto Decel
3: Auto Accel/Decel (Set by load)
4: Auto Accel/Decel (set by Accel/Decel
Time setting)
0.0 to 10.0 / 0.00 to 10.00 sec
0.0 to 10.0 / 0.00 to 10.00 sec
0: Unit: 0.1 sec
1: Unit: 0.01 sec
Group 2 Operation Method Parameters
0: Digital keypad UP/DOWN keys or Multi-
function Inputs UP/DOWN. Last used
frequency saved.
1: 0 to +10V from AVI
2: 4 to 20mA from ACI
3: RS-485 (RJ-45) communication
4: Digital keypad potentiometer
English
Settings
ADV20 QS, V1.02
Factory
NOTE
Setting
0
60.00
60.00
220.0
440.0
1.50
10.0
20.0
1.50
10.0
20.0
110.0
0.0
10.0
10.0
10.0
10.0
1.0
1.0
6.00
0
0.0
0.0
0
1
11