Output Function Parameters - gefran ADV20 series Quick Start-Up

Compact v/f ac drive 0.4 to 3.7 kw 115-230 vac 1ph, 230-460 vac 3ph
Table of Contents

Advertisement

Available languages

Available languages

Parameter
Explanation
Multi-function
03.00
Output Relay (RA1,
RB1, RC1)
03.01
Reserved
03.02
Desired Frequency
Attained
Analog Output
03.03
Signal Selection
(AFM)
03.04
Analog Output Gain
03.05
Terminal Count
Value
Preliminary Count
03.06
Value
EF Active When
03.07
Terminal Count
Value Attained
03.08
Fan Control
03.09
Reserved
03.10
Reserved
Brake Release
03.11
Frequency
Brake Engage
03.12
Frequency
14
ADV20 QS, V1.02
Group 3 Output Function Parameters
0: No function
1: AC drive operational
2: Master frequency attained
3: Zero speed
4: Over torque detection
5: Base-Block (B.B.) indication
6: Low-voltage indication
7: Operation mode indication
8: Fault indication
9: Desired frequency attained
10: Terminal count value attained
11: Preliminary count value attained
12: Over Voltage Stall supervision
13: Over Current Stall supervision
14: Heat sink overheat warning
15: Over Voltage supervision
16: PID supervision
17: Forward command
18: Reverse command
19: Zero speed output signal
20: Warning(FbE,Cexx, AoL2, AUE, SAvE)
21: Brake control (Desired frequency
attained)
0.00 to 600.0Hz
0: Analog frequency meter
1: Analog current meter
1 to 200%
0 to 9999
0 to 9999
0: Terminal count value attained, no EF
display
1: Terminal count value attained, EF active
0: Fan always ON
1: 1 minute after AC motor drive stops, fan
will be OFF
2: Fan ON when AC motor drive runs, fan
OFF when AC motor drive stops
3: Fan ON when preliminary heatsink
temperature attained
0.00 to 20.00Hz
0.00 to 20.00Hz
Settings
Italiano
Factory
NOTE
Setting
8
0.00
0
100
0
0
0
0
0.00
0.00
English

Hide quick links:

Advertisement

Table of Contents
loading