Rear Outlets Of Hydraulic Outer Circuit; Outlets Of Front Outer Circuit - Zetor 86 41 forterra turbo Operator's Manual

Table of Contents

Advertisement

REAR OUTLETS OF HYDRAULIC
OUTER CIRCUIT
Tractor without front quick - couplers and
front three point hitch, equiped with me-
chanical hydraulic systém and two-
section SCV have got quick - couplers
"1 - 6". Quick - couplers "3 - 6" are ope-
rated by levers of SCV.
The quick-coupler No "0" is connected
directly with differential case space and
is intended for turning the oil from hyd-
raulic implements (for example from ro-
tary hydro-motors etc.).
HYDRAULIC SYSTEM
F163c
REAR OUTLETS OF HYDRAULIC
OUTER CIRCUIT
Tractor without front quick - couplers and
front three point hitch, equiped with
EHR-B and three - section SCV have got
quick - couplers "1 - 6". This are opera-
ted by three levers of SCV.
The quick-coupler No "0" is connected
directly with differential case space and
is intended for turning the oil from hyd-
raulic implements (for example from ro-
tary hydro-motors etc.).
115
F163b

OUTLETS OF FRONT OUTER CIRCUIT

Front outlets are assembled on panel in
the front right part of tractor. Front out-
lets are assembled together with SCV.
They are intended for work with front at-
tached implements. Marking of outlets
and their use is the same as at rear
ones.
A - Tractor is equipped with hydraulic
equipment with two section SCV.
B - Tractor is equipped with electro-
hydraulicEHR-B and three section
SCV.
F168