Configuring The Port Status Detection Timer; Clearing Unused 16-Bit Interface Indexes - HP 6125G Configuration Manual

Fundamentals configuration guide
Hide thumbs Also See for 6125G:
Table of Contents

Advertisement

Step
4.
Add commands to the job.

Configuring the port status detection timer

Some protocols might shut down ports under specific circumstances. For example, MSTP shuts down a
BPDU guard enabled port when the port receives a BPDU. Then, the device starts the detection timer. If
the port is still down when the detection timer expires, the port quits the shutdown status and resumes its
actual physical status.
To configure the port status detection timer:
Step
1.
Enter system view.
2.
Configure the port status
detection timer.

Clearing unused 16-bit interface indexes

The device must maintain persistent 16-bit interface indexes and keep one interface index match one
interface name for network management. After deleting a logical interface, the device retains its 16-bit
interface index so the same index can be assigned to the interface at interface re-creation.
To avoid index depletion causing interface creation failures, you can clear all 16-bit indexes that have
been assigned but not in use. The operation does not affect the interface indexes of the interfaces that
have been created but the indexes assigned to re-recreated interfaces might change.
A confirmation is required when you execute this command. The command will not run if you fail to make
a confirmation within 30 seconds or enter N to cancel the operation.
To clear unused 16-bit interface indexes, perform the following task in user view:
Task
Clear unused 16-bit interface
indexes.
Command
Configure a command to run at a
specific time and date:
time time-id at time date command
command
Configure a command to run at a
specific time:
time time-id { one-off | repeating }
at time [ month-date month-day |
week-day week-daylist ] command
command
Configure a command to run after a
delay:
time time-id { one-off | repeating }
delay time command command
Command
system-view
shutdown-interval time
Command
reset unused porttag
115
Remarks
Use any of the commands.
NOTE:
Changing a clock setting does not
affect the schedule set by using the
time at or time delay command.
Remarks
N/A
The detection timer is 30 seconds
by default.
Remarks
In an IRF fabric, the command
applies to all member switches.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

5500 hi series6125 blade switch series

Table of Contents