System Alarm Connection Requirements - Paradyne Jetstream CPX-1000 Installation And Operation Manual

Voice services platform
Hide thumbs Also See for Jetstream CPX-1000:
Table of Contents

Advertisement

1000-A2-GN22-00
System Alarm
Connection
Requirements
1. Optically coupled, CMOS FET bipolar switches
February 2003
The CPX-1000 includes an Alarm board in the summary alarm
panel at the top of the shelf. This Alarm board continuously
monitors various internal system operating parameters and
reports alarms (if failures are detected). Dry Form-A closures
provided for critical, major, and minor alarm connections to
external local alarm surveillance equipment.
The closure specifications are:
Rated resistive load: 20 Ohms (typical) @ 50 mA, 5 Ohms
(typical) @ 100 mA
Rated inductive load: not applicable
Operating voltage: 100 VDC/VAC (350 VDC or peak ac for
100 ms transients)
Continuous load: 250 mA dc, 150 mA ac
Minimum load: 10
Critical alarm closure is normally closed. Major and minor closures
are normally open.
Table B–5. Remote Alarm Connector Pin Assignments
Pin
Signal
1
Critical Alarm
2
Critical Alarm Return
3
Major Alarm
4
Major Alarm Return
5
Minor Alarm
6
Minor Alarm Return
7
Rack Alarm (not used)
8
Rack Alarm Return (not used)
B. Pin Assignments and Indicators