Paradyne Jetstream CPX-1000 Installation And Operation Manual page 35

Voice services platform
Hide thumbs Also See for Jetstream CPX-1000:
Table of Contents

Advertisement

1000-A2-GN22-00
Table 2–1. Alarm Indicator Status and Description
Alarm Indicator
Slot Status
System Status
Telco Status
February 2003
Status
Description
Act
Module is in Active state (not Standby)
Unlocked
Module administrative state is Unlocked
Disabled
Module operational state is Disabled
Alert A
Not used
Alert B
Not used
Alert C
Not used
Minor
CPX minor alarm
Major
CPX major alarm
Critical
CPX critical alarm
The three Telco alarms and a rack alarm are also routed through a
dry contact relay to the RJ-45 remote alarm connector.
The standard Telco alarm signals and rack alarm are available as an
output to remote alarm equipment
Table 2–2. Remote Alarm Connector
Pin
Signal
1
Critical Alarm
2
Critical Alarm Return
3
Major Alarm
4
Major Alarm Return
5
Minor Alarm
6
Minor Alarm Return
7
Rack Alarm (not used)
8
Rack Alarm Return (not used)
2. CPX-1000 Voice Services Platform Description
(Table
2–2).
2-11

Advertisement

Table of Contents
loading

Table of Contents