Mark the rack for the location of each CPX shelf. Also mark the
shelf for optional STS-1 Splitter Assembly above each unit.
Caution
To help reduce risk of injury while lifting the shelf, reduce the
shelf weight by removing the power supply/fan modules.
When the shelf is in place, reinstall the modules.
Power Supply/Fan Modules
Loosen Retaining Screws
With the help of another person, lift the shelf into position through
the front of the shelf.
Using a flat-blade screwdriver, secure each flange with four 12-
1
24
-inch pan head screws to fasten the shelf to the rack.
×
2
Caution
Insert the power supply/fan module with a single, steady
motion.
If the power supply does not easily slide into the slot, back
the module out and re-insert it Do not force the power supply
into the shelf as you may bend the power supply pins.
Reinstall the power supply/fan modules.
Repeat these steps for each shelf to be mounted in the rack.
3. Installing the CPX-1000
Pull To Remove
0071
3-15