(2) General sewing functions (C Group)
Turn on the power pressing
No.
Functions and Description
When the electronic wiper is used (A15=1), set the standby time
C-01
from trimming to wiper motion.
C-02
Set the operating angle of the trimmer solenoid
and
. Turn on the memory switch pressing
1 255[ms]
1 250 [degrees]
.
P3
Scope
Default
Unit
1[ms]
165[ms]
1 [degrees]
40 [degrees]
27