Aupc Menu Options And Parameters - Radyne DMD15 Installation And Operation Manual

Radyne, inc. user guide modem installation dmd15, dmd15l
Table of Contents

Advertisement

User Interfaces
ES Baud:
ES Data Bits:

4.3.5 AUPC Menu Options and Parameters

Note: AUPC Menus are only available when the Modulator is in 'Closed Net' Mode and
Framing is 'EFAUPC 1/15'.
Local AUPC (menu):
AUPC Enable:
Nominal TX Power:
Minimum TX Power:
Maximum TX Power:
Target Eb/No:
4-14
DMD15/DMD15L IBS/IDR Satellite Modem
{150-19200}
Allows the user to select the baud rate in Enhanced
Async mode. Available rates are listed in Sect 3.20.1
{7,8}
Allows the user to choose between 7 or 8 bit data.
The 'LOCAL AUPC CONFIGURATION' Menu contains
the local configuration parameters for the AUPC
Function.
{Off, On}
Allows the user to enable or disable the Local AUPC
Function of the local modem. The Local AUPC Function
is the response to the commands for an increase or
decrease of the Transmit Power in 0.5 dB steps. The
command to change to the setting is indicated in the
'REMOTE CL ACTION' Menu upon receiver loss of lock
of the remote modem.
{variable through power range}
Allows the user to set the nominal Transmit Power. The
nominal Transmit Power is the setting that will be used
when the remote modem indicates that its receiver has
lost lock and commands a change to the setting
indicated in the 'REMOTE CL ACTION' Menu. That
change will only be implemented if the 'REMOTE CL
ACTION' Menu is set to "NOMINAL".
{variable through power range}
Allows the user to set the minimum Transmit Power.
The minimum Transmit Power is the lowest power
setting that will be used when the remote modem
commands a decrease of the Transmit Power.
{variable through power range}
Allows the user to set the maximum Transmit Power.
The maximum Transmit Power is the highest power
setting that will be used when the remote modem
commands an increase of the Transmit Power. It is the
setting that will be used when the remote modem
indicates that its receiver has lost lock and commands a
change to the setting indicated in the 'REMOTE CL
ACTION', Menu. That change will only be implemented
if the 'REMOTE CL ACTION' Menu is set to "MAXIMUM".
{variable}
Allows the user to set the desired E
receiver. This setting is compared against the receive
/N
for the local
b
o