Tracking Rate:
Local CL Action:
Remote CL Action:
TM051 - Rev. 5.8
E
/N
and commands to the remote modem to increase
b
o
or decrease Transmit Power accordingly are sent.
{0.5 to 6.0}
Allows the user to set the rate at which the commands to
increase or decrease Transmit Power are sent. Each
command will result in a 0.5-dB increase or decrease in
Transmit Power from the remote transmitter. The
tracking rate is adjustable from 0.5 dB per minute to 6.0
dB per minute in 0.5 dB steps. The resulting 'command
rate' is 1 command every minute to 1 command every
five seconds.
{HOLD, NOMINAL, MAXIMUM}
Allows the user to set the Transmit Power Setting to be
used when the local modem receiver loses lock. The
setting can be 'HOLD' (no action taken), 'NOMINAL' (the
nominal Transmit Power Setting is used), and
'MAXIMUM' (the maximum Transmit Power Setting is
used).
{HOLD, NOMINAL, MAXIMUM}
Allows the user to set the Transmit Power Setting to be
used when the remote modem receiver loses lock. The
setting can be 'HOLD' (no action taken), 'NOMINAL' (the
nominal Transmit Power Setting is used), and
'MAXIMUM' (the maximum Transmit Power Setting is
used).
User Interfaces
4-15