Radyne DMD15 Installation And Operation Manual page 128

Radyne, inc. user guide modem installation dmd15, dmd15l
Table of Contents

Advertisement

DMD15/DMD15L IBS/IDR Satellite Modem
Power
<2>
AUPC Maximum
Power
<2>
AUPC Nominal Power
Opcode: <2635h> Command AUPC Remote Configuration
<1>
AUPC Remote Enable
<1>
AUPC Remote BB
Loopback
<1>
AUPC Remote 2047
Opcode: <2636h> Command Modulator Reed Solomon N & K Codes and Interleaver Depth
<1>
Tx RS N Code
<1>
Tx RS K Code
<1>
Tx RS Depth
Opcode: <2638h> Command a modulator's Time Mark Transfer
<1>
Time Mark Transfer
Enable
<1>
Time Mark Transfer
Pattern Length
4.9.5.2 DMD15/DMD15L Demodulator
Opcode: <2401h> Query a demodulator's configuration and status
<1>
Number of nonvol
bytes
<1>
Mode
<4>
Frequency
<2>
Sweep Delay
<4>
Data Rate
<1>
Sweep Boundary
<1>
Input Level Limit
<2>
Strap Code
<1>
Filter Mask
TM051 - Rev. 5.8
dBm (two's compliment)
Singed value +50 to –200 with implied decimal point; 49 = +4.9
dBm (two's compliment)
Singed value +50 to –200 with implied decimal point; 49 = +4.9
dBm (two's compliment)
0 = Off, 1 = On
0 = Disable, 1 = Enable
0 = Disable, 1 = Enable
2 - 255. Reed-Solomon code word length
1 - 254. Reed-Solomon message length
4 or 8 Reed-Solomon Interleaver Depth
0 = Disable, 1 = Enable
Unsigned Binary (4 to 16) Inclusively
Query Response
Configuration Bytes
0 = Closed Net. 1 = IDR, 2 = IBS, 3 = D&I
Selects the IF frequency in Hz. The range is 50 MHz to 180
MHz for the 70/140 MHz type modems and 950 MHz to 1750
MHz for the L-Band Modems.
Unsigned binary value, decimal point implied, 0.1 second steps
0.0 – 900.0
Binary value, 1 bps steps
Sweep limits. Max of ± 32 kHz in kHz steps 1 - 32
Lower level limit, binary value, 1 dB steps. Reserved
Binary value
0 = INTELSAT, 1 = EUTELSAT, 2 = CLOSED NET1
User Interfaces
4-77

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dmd15l ibsDmd15 ibsDmd15 idrDmd15l idr

Table of Contents