Radyne DMD15 Installation And Operation Manual page 151

Radyne, inc. user guide modem installation dmd15, dmd15l
Table of Contents

Advertisement

User Interfaces
<1>
Common Alarm 2
Opcode: <240Dh> Query a modem's Eb/No, BER, and Level
<2>
Raw BER Mantissa
<2>
Corrected BER
Mantissa
<2>
EbNo
<1>
Raw BER Exponent
<1>
Corrected BER
Exponent
<1>
BER/EbNo Status
<1>
Input Level
Opcode: <240Eh> Query time
<1>
Hour
<1>
Minute
<1>
Second
Opcode: <240Fh> Query date
<1>
Year
<1>
Month
<1>
Day
Opcode: <2410h> Query time and date
<1>
Year
<1>
Month
4-100
Bit 0 = M&C processor fault. 1 = Fail
Bit 1 = U IO card present. 1 = Present, reserved in RCS10/10L
mode
Bit 2 = IF card present. 1 = Present
Bits 3 - 7 = Spares
Query Response
Bytes 1 - 2 = Binary value Raw BER 896 = 8.96
Bytes 1 - 2 = Binary value corrected BER
Binary value, 1 decimal point implied 700 = 7.00
Byte 3 = Binary value exponent
Byte 3 = Binary value exponent
Bit 0 = Raw BER and corrected BER status. 1 = Valid
Bit 1 = Test 2047 BER status. 1 = Valid
Bits 2 - 3 = EbNo status, 0 = EbNo is invalid, 1 = EbNo is valid,
2 = EbNo is smaller than indicated, value, 3 = EbNo is greater
than indicated value
Bit 4 = BER Counter Overflow. 1 = Overflow Condition
Bit 5 = Test 2047 BER Counter Overflow 1 = Overflow
Condition
Bits 6 – 7 = Reserved
Binary value in 1 dB steps
Query Response
0 – 23
0 – 59
0 – 59
Query Response
0 - 99
0 - 11
0 – 30
Query Response
0 - 99
0 - 11
DMD15/DMD15L IBS/IDR Satellite Modem
TM051 – Rev. 5.8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dmd15l ibsDmd15 ibsDmd15 idrDmd15l idr

Table of Contents