Earth Station To Earth Station (Es-Es) Communications Port; (Async Port J9); Terrestrial Loopback; Modem Status - Radyne DMD15 Installation And Operation Manual

Radyne, inc. user guide modem installation dmd15, dmd15l
Table of Contents

Advertisement

DMD15/DMD15L IBS/IDR Satellite Modem
can be connected to the 'Insert Data In' Port where received data will overwrite 'dropped on' the
T1/E1 Data Stream. The modified T1/E1 Data Stream will then exit the modem out of the
'Receive Data Out' Port.

3.5 Earth Station to Earth Station (ES-ES) Communications Port

(Async Port J9)

The UIM contains a selectable RS-232, or RS-485 Asynchronous Communications Port for Earth-
Station-to-Earth-Station Communications. The data is routed from the 9-Pin "D" Connector J9 to
one of the M&C Processor UARTS on the Baseband Processor Card. The baud rate and protocol
can be selected from the Front Panel.

3.6 Terrestrial Loopback

The UIM also provides for terrestrial loopback. For Tx Terr Loopback, Tx Data, after passing
through the Line Interface is looped back to the Rx Data line drivers. For RX Terr Loopback, the
Receive Data from the satellite is looped back for retransmission to the satellite providing a far
end loopback. Tx/Rx Loopback provides both loopbacks simultaneously. Refer to Figures 3-4
through 3-6 for loopback functional block diagrams.

3.7 Modem Status

The UIM provides several status indications, which are controlled by the M&C Processor.
Form-C Contacts:
The UIM provides three Form-C Relays under processor control that appear at J11.
Mod Fault:
Demod Fault:
Common Fault:
Open Collector Faults:
The UIM provides two Open Collector Faults that appear at Pins 28 & 10 on J8.
Mod Fault:
Demod Fault:
The open collector faults are intended for use in redundancy switch applications in order to
provide quick status indications.
TM051 - Rev. 5.8
De-energized when any transmit side fault is detected.
De-energized when any receive side fault is detected.
De-energized when any fault that is not explicitly a Tx or
Rx Fault such as an M&C or Power Supply Fault.
Will sink up to 20 ma (maximum) until a transmit or
common fault is detected. Will not sink current if a fault
is detected.
Will sink up to 20 ma (maximum) until a receive or
common fault is detected. Will not sink current if a fault
is detected.
Operation
3-5

Hide quick links: