2.8 Backing Up Electronic Labels

You can back up electronic labels to improve network maintenance efficiency.
Context
Electronic labels can help locate network faults and replace hardware in batches. Therefore,
backing up electronic labels is a must.
l
l
Electronic labels can be backed up to the FTP server, TFTP server, or storage media. Before
backing up electronic labels to the FTP or TFTP server, ensure that there are reachable routes
between the device and FTP server (or TFTP server).
Procedure
l
l
l
----End

2.9 Forcing the RPS to Supply Power for the Device

You can force the redundant power system (RPS) to supply power for the device to ensure normal
device running.
Context
The RPS functions as the external backup power supply for the device. When a fault occurs in
the internal power supply system, the RPS can supply power for the device in a timely manner
to ensure normal device running. When the fault is rectified, the RPS stops supplying power for
the device.
Issue 05 (2014-01-16)
When a network fault occurs, you can rapidly learn about hardware information using
electronic labels, which improves hardware maintenance efficiency. In addition, you can
efficiently analyze and trace the defects in the hardware by analyzing electronic labels
statistics on the faulty hardware.
Before replacing hardware in batches, you can use the electronic labels recorded in the
archive systems of customers' devices to obtain accurate hardware deployment information.
Then you can evaluate the impact of hardware replacement and define policies to efficiently
replace hardware in batches.
Run:
backup elabel filename [ slot-id ]
Electronic labels are backed up to the flash memory, USB flash drive, or SD card.
Run:
backup elabel ftp ftp-server-address filename username password [ slot-id ]
Electronic labels are backed up to the FTP server.
Run:
backup elabel tftp tftp-server-address filename [ slot-id ]
Electronic labels are backed up to the TFTP server.