system-view
The system view is displayed.
Step 2 Run the following command as required.
l Run:
info-center loghost ip-address [ channel { channel-number | channel-name } |
facility local-number | { language language-name | binary [ port ] } | { vpn-
instance vpn-instance-name | public-net } ]
The device is configured to output traps to the IPv4 log host.
l Run:
info-center loghost ipv6 ipv6-address [ channel { channel-number | channel-
name } | facility local-number | { language language-name | binary [ port ] } ]
*
The device is configured to output traps to the IPv6 log host.
By default, the Router does not output traps to a log host.
The device supports a maximum of eight log hosts including IPv4 and IPv6 hosts to implement
backup among log hosts.
Step 3 Run:
info-center source { module-name | default } channel { channel-number | channel-
name } trap { state { off | on } | level severity }
A rule for outputting traps to a channel is set.
By default, channel 2 is enabled to output traps and the lowest severity is debugging.
Step 4 (Optional) Run:
info-center loghost source interface-type interface-number
The source interface used by the device to send logs to a log host is specified.
By default, the source interface is the interface that sends logs.
After the source interface is specified, the log host determines the device that sends messages.
The log host then can easily retrieve received messages.
----End

3.6.2.10 Configuring the Device to Output Traps to an SNMP Agent

Context
When an exception or a fault occurs on the device, the network administrator needs to learn the
device running status. You can configure the device to output traps to an NMS server so that the
network administrator can monitor the device in real time and locate faults immediately. Before
configuring the device to output traps to an NMS server, configure the device to output traps to
an SNMP agent. Then the SNMP agent sends traps to the NMS server.
Procedure
Step 1 Run:
system-view
Issue 05 (2014-01-16)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 Information Center Configuration
*
*
51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar1200 seriesAr200 seriesAr2200 seriesAr3200 series

Table of Contents