Maintenance; Clearing Alarms And Events - Huawei AR150 Series Configuration Manual

Hide thumbs Also See for AR150 Series:
Table of Contents

Advertisement

Huawei AR150&200&1200&2200&3200 Series Enterprise
Routers
Configuration Guide - Device Management
Step 5 (Optional) Run:
suppression event-name event-name period seconds
The period of delay in reporting events is configured.
The system has defined a default period of delay in reporting events.
NOTE
Run the undo suppression event-name and display event information commands in sequence to
view the default period of reporting delay.
----End
Checking the Configuration
l
l

4.4.3 Maintenance

This section describes how to monitor and clear alarms and events.

4.4.3.1 Clearing Alarms and Events

Context
The cleared alarm or event statistics cannot be restored. Confirm the action before you run the
command.
Procedure
l
l
Issue 05 (2014-01-16)
Run the display event information [ name event-name ] command to view
the event configuration.
Run the display this command in the event view to view the event configuration.
NOTICE
Clearing alarms
1.
Run:
system-view
The system view is displayed.
2.
Run:
alarm
The alarm view is displayed.
3.
Run:
clear alarm active { all | sequence-number sequence-number
Active alarms on the device are cleared.
Clearing events
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Fault Management Configuration
}