Huawei AR150&200&1200&2200&3200 Series Enterprise
Routers
Configuration Guide - Device Management
l
l
Issue 05 (2014-01-16)
The interface view is displayed.
b.
Run:
poe priority { critical | high | low }
The power supply priority of the interface is set.
The priorities in descending order are critical, high, and low.
By default, the power supply priority of an interface is low.
– In manual power management mode, PDs connected to each interface are manually
powered on or powered off. In manual mode, you can select some PDs to power
on or power off as required.
a.
Run:
system-view
The system view is displayed.
b.
Run:
poe { power-on | power-off } interface interface-type interface-
number
The PD connected to an interface is powered on or powered off manually.
(Optional) Set the power-off time range of a PoE interface.
PDs connected to an interface do not keep working. You can set the power-off time range
of a PoE interface so that it can automatically power off when it is idle to save energy.
1.
Run:
system-view
The system view is displayed.
2.
Run:
time-range time-name { start-time to end-time days | from time1 date1
[ to time2 date2 ] }
A power-off time range of PoE is defined.
3.
Run:
interface interface-type interface-number
The interface view is displayed.
4.
Run:
poe power-off time-range time-range-name
A configured PoE power-off time range is applied to an interface.
(Optional) Configure the device to be compatible with non-standard PDs
When a non-standard PD is connected to the device, the device cannot detect the proper
resistance and cannot identify the PD. When compatibility check is enabled, the device can
detect and provide power for the PD that does not comply with the 802.3af or 802.3at
standard.
1.
Run:
system-view
The system view is displayed.
2.
Run:
interface interface-type interface-number
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6 PoE Configuration
140