Prime Pump - New Holland TS-100A Assembly & Instruction Manual

Cab 2 wd / 4 wd
Table of Contents

Advertisement

Hydraulic Oil Installation 2 WD & 4 WD
10°F
Figure 4
Prime Hydraulic Pump:
The Hydraulic Pump
1.
MUST be Primed.
draulic pump is primed by putting
oil directly in to the pump. Looking
at the pump, out near the end of the
pump there is a Allen plug (See
Figure 5). Remove this plug and
install only approved hydraulic oil (
See Step 1 through 3 of hydraulic
tank filling). Fill the cavity completely
full up to plug threads. IMPOR-
TANT! This must be done before
the unit is ever started. Make cer-
tain that the O-Ring Seal is on plug
and reinstall it after cavity is full of
oil, now the pump is primed. The
Unit still will not operate until the
next step of setting the electronics
to operate the system.
New Holland (NH TS-100A, 115A, 125A, 135A Asy. Man) 01/05
© 2005 Alamo Group Inc.
ATTENTION
20°F
30°F
AW ISO VG 32
AW ISO VG 46
The correct hydraulic fluid is dependent upon ambient
temperature. Refer to chart when selecting proper grade
The hy-
Figure 5
40°F
60°F
70°F
AW ISO VG 68
AW ISO VG 100
Remove This allen head
Section 10 - 3
90°F 110°F
02982828
plug to Prime Pump