SECTION MITL9141-753-503-NA
Page 10
4 . 0 4 The pinout
Pin
1
2
3
4
5
6
7
8
9
11
12
installation
4.05
Complete system cabling and Customer Data Entry for the slot
into which the DATASET is being installed; cabling is defined in
DATASHELF
4.06
Install a DATASET 1102 Dual Rack Mounted card by plugging it
into its assigned slot in the DATASHELF 9100. All LEDs (except
POWER 1) should flash 5 times, indicating that the DATASET has
passed its self-test. If this does not happen, the DATASET is faulty and
must be replaced.
4.07
The POWER 2 LED should be on continuously, indicating con-
nection to the Digital Line Card. If the POWER 2 LED is flashing,
check the wiring between the DATASET and the PABX, and Customer
Data Entry (CDE) for the device.
Plug
4.08
nector at the back of the DATASET 1102 Rack Mounted cards
and connect them to the host device. When the RS-232 connector is
attached, the DEVICE LED should be on, unless the device is an auto-
answer device, and defined as such in CDE (usually only destination
devices such as host computers are auto-answer). If the device is not
auto-answer, and the DEVICE LED does not come on, do the following:
1)
Make sure the device is powered on
2)
Use an RS-232 break-out box to verify that the device provides
DTR. If the device does not provide DTR, select CDE option
"RS-232 Force High" for that device.
of the card edge connector is as follows:
Signal
data ring
no connection
frame ground
signal ground
T2 (ac input)
T2 (ac input)
signal ground
frame ground
no connection
data tip
9100
installation
procedures.
the
RS-232
interconnecting
cables
into
the
RS-232
con-