S.04.002
Minimum
Default
Type
Display Format
Coding
When read, this parameter will indicate the state of Digital Input 2. An inactive input (low) will give
the value 0 and active input (high) will give 1.
S.04.003
Minimum
Default
Type
Display Format
Coding
When read, this parameter will indicate the state of Digital Input 3. An inactive input (low) will give
the value 0 and active input (high) will give 1.
S.04.004
Minimum
Default
Type
Display Format
Coding
When read, this parameter will indicate the state of Digital I/O 4. An inactive input (low) will give the
value 0 and active input (high) will give 1.
When this terminal is configured as an output (using Digital Input/Output 4 Direction (S.04.021)),
this parameter is still accessible and will indicate the state of the terminal not the requested output
value e.g. if the user tries to set the output high, but, due to a wiring error, the output is being held
low, this parameter will give the value 0.
S.04.010
Minimum
Default
Type
Display Format
Coding
When written, this parameter will set the state of Digital Output 5. Setting to 0 will place the output
low and setting to 1 will place the output high.
36
Digital Input 2 State
0
1 Bit Volatile
None
RO, ND, NC, PT
Digital Input 3 State
0
1 Bit Volatile
None
RO, ND, NC, PT
Digital Input/Output 4 State
0
1 Bit Volatile
None
RO, ND, NC, PT
Digital Output 5 State
0
0
1 Bit Volatile
None
RW
Maximum
Units
Update Rate
Decimal Places
Maximum
Units
Update Rate
Decimal Places
Maximum
Units
Update Rate
Decimal Places
Maximum
Units
Update Rate
Decimal Places
1
Immediate
0
1
Immediate
0
1
Immediate
0
1
Immediate
0