Emerson MCi210 User Manual page 22

Table of Contents

Advertisement

S.01.015
Minimum
Default
Type
Display Format
Coding
When this parameter is 0 the module will reset when a drive trip is cleared. When the parameter is
set to On, the module will continue running (i.e. not reset) when a drive trip is cleared.
S.01.017
Minimum
Default
Type
Display Format
Coding
When this parameter is 0, and an out of range value is written to a parameter, then the value will be
automatically limited to that parameter's maximum or minimum value.
When this parameter is 1, and an out of range value is written to a parameter, then a run-time error
(code 44) will occur.
S.01.019
Minimum
Default
Type
Display Format
Coding
When set the module will save any retain data that the user has defined, up to a maximum of 2 kB.
When the save is complete, the parameter will be cleared to zero. The save will be processed as a
background task and will not affect any scheduled user tasks.
S.01.020
Minimum
Default
Type
Display Format
Coding
The parameter allows the user to define the action on the retain data when the drive enters under
voltage state.
When set to 0 no action will be taken and the retain data will not be saved.
When set to 1 the retain data will be automatically saved when the drive enters the under voltage
state.
22
Disable reset on trip clear
0
0
1 Bit User Save
None
RW
Enable out of range error
0
0
16 Bit Volatile
None
RW
Save retain data request
0
0
1 Bit Volatile
None
RW, NC
Power down retain data save
0
1
8 Bit User Save
None
RW, Txt, NC
Maximum
Units
Update Rate
Decimal Places
Maximum
Units
Update Rate
Decimal Places
Maximum
Units
Update Rate
Decimal Places
Maximum
Units
Update Rate
Decimal Places
1
Background read
0
1
Background read
0
1
Read every 200 ms
0
2
When Under Voltage is
detected
0
MCi210 User Guide
Issue Number: 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents