S.11.020
Minimum
Default
Type
Display Format
Coding
The parameter displays a count of network errors since start up. It can be used as an indication of a
problem.
S.11.030
S.11.031
S.11.032
Minimum
Default
Type
Display Format
Coding
This defines the allowable network delay (in milliseconds) for the associated Easy mode cyclic link.
A value of zero implies a non-synchronized link.
S.11.040
S.11.050
S.11.060
Minimum
Default
Type
Display Format
Coding
Value
0
Off
1
Trip
2
Do not use
3
Use
This parameter defines the action to be taken when a late synchronized frame is received.
MCi210 User Guide
Issue Number: 2
Network Error Count
0
32 Bit Volatile
None
RO, ND, NC, PT, BU
Tx1 Link Maximum Network Delay
Tx2 Link Maximum Network Delay
Tx3 Link Maximum Network Delay
0
0
8 Bit User Save
None
RW, BU
Rx1 Link Late Synchronization Frame Action
Rx2 Link Late Synchronization Frame Action
Rx3 Link Late Synchronization Frame Action
0
0
8 Bit User Save
None
RW, Txt, BU
Text
Link is not synchronized
Trip drive with Slotx Error and sub-trip code
The data is ignored
The data is used immediately
Maximum
Units
Update Rate
Decimal Places
Maximum
Units
Update Rate
Decimal Places
Maximum
Units
Update Rate
Decimal Places
Description
4294967295
Written every 500 ms
0
100
Read on reset
0
3
Read on reset
0
59