S.11.006
Minimum
Default
Type
Display Format
Coding
This parameter displays the Synchronization jitter in nanoseconds. The value is filtered to be
human readable.
S.11.007
Minimum
Default
Type
Display Format
Coding
This parameter sets the application tolerable clock jitter in ns from the grandmaster. If
Synchronization Jitter From Grandmaster (S.11.006) is within the tolerance the local clock is
synchronized to the grandmaster and synchronized cyclic data links will be processed.
S.11.008
Minimum
Default
Type
Display Format
Coding
The parameter displays the module's synchronization status. 1 = Synchronized, 0 = Not
synchronized.
S.11.009
Minimum
Default
Type
Display Format
Coding
This parameter controls whether the module synchronizes the OPT_SYNC with the network
grandmaster. A value of On (1) inhibits this.
56
Synchronization Jitter From Grandmaster
-2147483648
32 Bit Volatile
None
RW, ND,NC, PT
Synchronization Jitter Threshold
10
1000
32 Bit User Save
None
RW, BU
Module Synchronized Flag
0
1 Bit Volatile
None
RO, ND, NC, PT
Inhibit Drive Synchronization
0
0
1 Bit User Save
None
RW
Maximum
Units
Update Rate
Decimal Places
Maximum
Units
Update Rate
Decimal Places
Maximum
Units
Update Rate
Decimal Places
Maximum
Units
Update Rate
Decimal Places
2147483647
ns
Written every 500 ms
0
4294967295
ns
Read on reset
0
1
Written every 10 ms
0
1
Immediate
0