S.11.014
Minimum
Default
Type
Display Format
Coding
This enables the clock to provide time information using a single event message. If disabled the
clock will provide time information using the combination of an event message and a subsequent
general message.
S.11.015
Minimum
Default
Type
Display Format
Coding
Value
0
1
This parameter selects the delay measurement. 0 = End-to-end; 1 = Peer-to-peer
End-to-end is the delay mechanism between slave clocks and the master clock.
Peer-to-peer delay mechanism provides not only the PTP event transit time information, but also
provides the corrections for the propagation delay of the link connected to the port receiving the
PTP event message.
S.11.016
Minimum
Default
Type
Display Format
Coding
This parameter controls the rate at which PTP Sync frames are sent. The message rate is
determined by raising 2 to the power of this parameter. E.g the default value of -2, results in four
sync messages per second.
58
1 Step Clock Correction
0
1
1 Bit User Save
None
RW, Txt, BU
PTP Delay Measurement Select
0
1
8 Bit User Save
None
RW, Txt, BU
Text
E2E Delay
P2P Delay
PTP Sync Rate
-4
-2
8 Bit User Save
None
RW
Maximum
Units
Update Rate
Decimal Places
Maximum
Units
Update Rate
Decimal Places
Description
End-to-end delay
Peer-to-peer delay
Maximum
Units
Update Rate
Decimal Places
1
Read on reset
0
1
Read on reset
0
4
Read on reset
0