Emerson MCi210 User Manual page 50

Table of Contents

Advertisement

S.10.044
S.10.054
S.10.064
Minimum
Default
Type
Display Format
Coding
Value
0
Direct
1
Multicast1
2
Multicast2
3
Multicast3
4
Multicast4
This parameter specifies the type of transmission for the receive link.
S.10.045
S.10.055
S.10.065
Minimum
Default
Type
Display Format
Coding
This parameter specifies the watchdog timer for the receive link. If no cyclic data is received on the
receive link the action taken will be determined by the setting in Rx Timeout Action (S.10.046,
S.10.056 or S.10.066).
It is good system design to allow for some message loss by setting the timeout duration
NOTE
to be greater than the transmit period by a factor of 2 or more.
50
Rx1 Link Source Type
Rx2 Link Source Type
Rx3 Link Source Type
0
0
8 Bit User Save
None
RW, Txt, BU
Text
Link is Unicast or Broadcast
Link is multicast to the IP Address
Link is multicast to the IP Address
Link is multicast to the IP Address
Link is multicast to the IP Address
Rx1 Link Timeout
Rx2 Link Timeout
Rx3 Link Timeout
0
100
16 Bit User Save
None
RW, BU
Maximum
Units
Update Rate
Decimal Places
Description
Maximum
Units
Update Rate
Decimal Places
4
Read on reset
0
65535
ms
Read on reset
0
MCi210 User Guide
Issue Number: 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents