Main SP Tables-1
Fusing Temperature Adjustment
Allows adjustment of the hot roller temperature at the center and ends of the
roller for the quality or thickness of the paper. The hot roller in this machine
has two fusing lamps: one heats the center of the roller, the other heats both
1105*
ends. Each fusing lamp can be adjusted separately.
The "re-load temperature" is the "print ready temperature". When the fusing
temperature exceeds this setting, the machine can operate. Do not set up a
re-load temperature (Re-load Temp. = Fusing. Temp – SP Value.) that is
higher than the SP1-105-2 setting.
Roller Center
001
Adjusts the fusing temperature at the center of the hot roller.
Roller Ends
002
Adjusts the fusing temperature at the ends of the hot roller.
Re-load Temp. Minus: Roller Center
Sets the reload temperature for the center of the hot roller. This setting
depends on the target temperature.
003
Reload temp. = Target Temp – This SP Setting
Do not set a temperature that is higher than the setting for SP1105 1
(Roller Center: Trays)
Re-load Temp. Minus: Roller Ends
Sets the reload temperature for the ends of the hot roller. This setting depends
on the target temperature.
004
Reload temp. = Target Temp – This SP Setting
Do not set a temperature that is higher than the setting for SP1105 2
(Roller Ends: Trays)
005 to
The following SPs adjust the fusing temperature at the center or ends of the
022
hot roller for each paper type.
D129/D130
C2b: [100 to 170 / 140 / 1 deg]
C2c: [100 to 170 / 150 / 1 deg]
C2b: [100 to 170 / 145 / 1 deg]
C2c: [100 to 170 / 155 / 1 deg]
[0 to 60 / 0 / 1 deg]
[0 to 60 / 0 / 1 deg]
5-6