Main SP Tables-5
Error Alarm
Sets the number of sheets to clear the error alarm counter.
The error alarm counter counts "1" when any SC is detected. However, the
error alarm counter decreases by "1" when an SC is not detected during a
5505*
set number of copied sheets (for example, default 5000 (C1b) or 10000
(C1c) sheets). The error alarm occurs when the SC error alarm counter
reaches "5".
[0 to 255 / 45 (C2b), 50 (C1b/C1.5b), 60 (C2c), 100 (C1c/C1.5c) / 100
copies / step]
5508
CC Call
001 Jam Remains
002 Continuous Jams
003 Continuous Door Open
011 Jam Detection: Time Length
Jam Detection Continuous
012
Count
013 Door Open: Time Length
D129/D130
Enables/disables initiating a call.
[0 to 1 / 1 / 1]
0: Disable
1: Enable
Sets the length of time to determine the
length of an unattended paper jam.
[3 to 30 / 10 / 1 minute]
Sets the number of continuous paper jams
required to initiate a call.
[2 to 10 / 5 / 1 time]
Sets the length of time the remains opens
to determine when to initiate a call.
[3 to 30/ 10 / 1 minute]