Communication error of the remote service modem
650
-
(Embedded RCG-M)
Authentication error
The authentication for the Embedded RCG-M fails at a dial up connection.
Incorrect SP settings
-001
-
Disconnected telephone line
Disconnected modem board
Check and set the correct user name (SP5816-156) and password
(SP5816-157).
Incorrect modem setting
Dial up fails due to the incorrect modem setting.
-004
-
Same as -001
Check and set the correct AT command (SP5816-160).
Communication line error
The supplied voltage is not sufficient due to a defective communication line
-005
-
or defective connection.
Same as -001
Consult with the user's local telephone company.
Modem board error 1
The modem board does not work properly even though the setting of the
modem board is installed with a dial up connection.
-013
-
Same as -001
1.
Install the modem board.
2.
Check and reset the modem board setting with SP5816.
3.
Replace the modem board.
Modem board error 2
The modem board is installed even though the RCG-N is installed.
-014
-
1.
Uninstall the modem board, if it is installed.
2.
Check that the Wireless LAN or Ethernet LAN is working properly.
SM
6-25
Service Call Conditions
D129/D130