Jam Alarm
Sets the alarm to sound for the specified jam level (document misfeeds are
not included).
[0 to 3 / 3 / 1 step]
5504*
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
Error Alarm
Sets the number of sheets to clear the error alarm counter.
The error alarm counter counts "1" when any SC is detected. However, the
error alarm counter decreases by "1" when an SC is not detected during a
5505*
set number of copied sheets (for example, default 5000 (C1b) or 10000
(C1c) sheets). The error alarm occurs when the SC error alarm counter
reaches "5".
[0 to 255 / 45 (C2b), 50 (C1b/C1.5b), 60 (C2c), 100 (C1c/C1.5c) / 100
copies / step]
5507*
Supply Alarm
Paper supply Alarm
001
(0:Off 1:On)
Staple Supply Alarm
002
(0:Off 1:On)
SM Appendix
Switches the control call on/off for the paper
supply. (DFU)
0: Off, 1: On
0: No alarm.
1: Sets the alarm to sound for the specified
number transfer sheets for each paper size (A3,
A4, B4, B5, DLT, LG, LT, HLT)
Switches the control call on/off for the stapler
installed in the finisher. (DFU)
0: Off, 1: On
0: No alarm
1: Alarm goes off for every 1K of staples used.
3-101
System SP Tables-5
D129/D130