Table 11-6 I/O Box Options (Outputs) (Continued)
AT TEMP
R. STANDBY
AT BOOST
RUN LIGHT
MOLD COOL
TEMP ERR
AT STANDBY
COMM ERR
90
v 1.4 — September 2015
Option Name
If the AT TEMP (at temperature) dry contact output option is turned on,
it will be activated ONLY when all zones are above the Under
Temperature alarm limit. This state will remain until any zone drops
below the Under Temperature alarm limit.
If the R. STANDBY (Remote Standby) dry contact output option is turned
on, it will be activated when Neo2 has received the Remote Standby
signal.
If the AT BOOST (at boost) dry contact output option is turned on, it will
be activated ONLY when all zones are above the under temperature
alarm limit while in BOOST mode. This state will remain until any zone
drops below the under temperature alarm limit. If any or all zones go
above the over temperature alarm limit the state will remain.
If the RUN LIGHT Output dry contact output option is turned on, it will be
activated whenever the system is running. This state will remain until the
system is stopped.
The Mold Cooling signal is activated based on the temperature limit set
on the Mold Cooling Enabled button in the Options screen.
If the controller is heating up (Start button is pressed), then the output
changes state once all zone temperatures are above the Mold Cooling
Enable limit
If the controller is cooling down (Stop button is pressed), then the
output returns to its original state once all of the zone temperatures are
below the Mold Cooling Enable limit
If the TEMP ERR (over maximum temperature error) dry contact output
option is turned on, it will be activated when any zone exceeds the Over
Maximum Temperature limit.
This signal is activated only when all zones are above the under
temperature alarm limit while in STANDBY mode. This state should
remain until any zone drops below the under temperature alarm limit.
Additionally, If any or all zones go above the over temperature alarm
limit the state will remain.
If the Comm Error dry contact output option is turned on, it will get
activated if Neo2 stops communicating with any of the Control Cards.
This state will remain until communications are restored.