7.2.3 Changing the Zone Regulation

Each zone in Neo2 has the ability to run in one of two control modes, Automatic (closed loop)
or Manual (open loop). This is referred to as zone regulation.
A control mode must be specified for each zone. The default setting is AUTO (automatic).
To change the zone regulation:
1.
2.
3.
4.

7.2.4 Changing the Standby Setpoint

It may be necessary to lower the temperatures in the mold for a period of time. Neo2 gives
the operator the ability to do this by touching one button without having to change the
normal setpoint. The standby temperature setpoint for the heaters must be specified, this
value is used when the STANDBY button is touched. The default setting is 121 °C (250 °F).
IMPORTANT!
Entering a value of 0 will place the selected zones into a NO CHANGE (---) mode. When in this
mode, these zones will not change their setpoint when the STANDBY button is touched.
To change the standby setpoint:
1.
2.
3.
4.
Changing the Zone Regulation
v 1.4 — September 2015
On the Quick Set screen, touch the zone to adjust.
To select more than one zone, touch the additional zones and they will be selected.
Using the Parameter Scroll buttons, scroll to REGULATION.
Touch REGULATION to toggle the selected zones from AUTO to MANUAL or vice versa.
Touch OK.
On the Quick Set screen, touch the zone to adjust.
To select more than one zone, touch the additional zones and they will be selected.
Using the Parameter Scroll buttons, scroll to STANDBY SETPOINT.
Touch STANDBY and a numerical Key window appears.
Enter the new setpoint, and then touch Enter.
The operator can also add or subtract from the current setpoint by entering the number
and touching the + or - button. For example, to add 4 degrees to the selected zones
setpoint, touch the 4 button followed by the + button.
NOTE:
Neo2 will remain in Standby until the STANDBY button is touched again or
until the manual standby timer expires, if set.