7.3.7 Changing the Automatic Manual Control (AMC) Setting

If a thermocouple malfunctions during normal operation, the software can automatically
apply a manual power output percentage to the heater based on the information gathered
before the thermocouple failed. This feature is called Automatic Manual Control (AMC).
If a thermocouple fails and AMC is turned ON (Yes), the control changes the failed zone into
manual mode and sets a manual power output based on the previously recorded average
power output to that heater. If AMC is turned OFF (No), the control skips to PCM (Priority
Control Mode) and performs the designated task. The default setting is ON for all zones.
NOTE:
To change the AMC setting:
1.
2.
3.
4.

7.3.8 Changing the Power Limit Setting

The Power Limit setting allows the operator to set the maximum amount of power that can
be delivered to the heaters. The default power limit for all zones is 100%.
To change the Power Limit setting for a zone:
1.
2.
3.
4.
5.

7.3.9 Changing the Earth Leakage Setting

In some cases there may not be a need to check for earth leakage errors on some zones. Neo2
has the ability shut the earth leakage check off on one or more zones in the system. The
default setting is YES on all zones which means all zones are checking for earth leakages
whenever the start button is touched.
NOTE:
To change a Earth Leakage setting:
1.
2.
3.
4.
Changing the Automatic Manual Control (AMC) Setting
v 1.4 — September 2015
Make sure the present security level is allowed to make this change.
On the Quick Set screen, touch the zone to change.
Using the Parameter Scroll buttons, scroll to AMC.
Touch AMC to toggle the selected zones from YES to NO or vice versa.
Touch OK.
On the Quick Set screen, touch the zone to adjust.
To select more than one zone, touch the additional zones and they will be selected.
Using the Parameter Scroll buttons, scroll to POWER LIMIT.
Touch POWER LIMIT and a numerical key window appears.
Enter the new value, and then touch Enter. The range is 0% to 100%.
Touch OK.
Make sure the present security level is allowed to make this change.
On the Quick Set screen, touch the zone to change.
Using the Parameter Scroll buttons, scroll to EARTH LEAKAGE.
Touch EARTH LEAKAGE to toggle the selected zones from YES to NO or vice versa.
Touch OK.