13.1.8 Controller Status

Summary
Errors
108
v 1.4 — September 2015
This command is used to read the condition of a single zone. The
definition of the status bits is given below:
BIT
SPI DEFINITION
0
Heater Power
1
Soft Start
2
Manual Control
3
Low Alarm 1
4
High Alarm 1
5
Low Alarm 2
6
High Alarm 2
7
Open T/C Alarm
8
Reverse T/C Alarm
9
Shorted T/C Alarm
10
Open Output Device
11
Shorted Output
12
Earth Leakage
13
Low Current Alarm
14
High current
15
Out Of Control
The following conditions result in an invalid data error in response to a
polled function:
Invalid zone number.
Altanium Neo2
SYSTEM DEFINITION
Power to heater is not zero
Soft start is active
Manual regulation (Not Auto
or View)
Alarm under temperature
Alarm over temperature
Abort under temperature
Abort over temperature
Lost thermocouple
Reversed thermocouple
Not supported
Fuse blown
Not supported
Not supported
Not supported
Not supported
Not supported
Controller Status