Yes: The setting can be changed, or the feature can be performed.
No: The setting cannot be changed, or the feature cannot be performed.
1 This setting or operation is unavailable when high speed data capturing has been started (Start).
2 This setting or operation is unavailable when a high speed data capturing file is being recorded to
(Rec).
3 When the wiring system of a wiring unit has been set to a single-phase, three-wire system (1P3W)
or a three-phase, three-wire system (3P3W), the voltage (UΣ), current (IΣ), and power (PΣ) of that
wiring unit are not measured and are displayed as "-------" (no data).
4 When the NULL feature is enabled and this setting or operation would cause a current input switch
between direct input and external current sensor input, this setting or operation is unavailable.
Perform this setting or operation in the normal measurement mode.
5 When the NULL feature is enabled, you cannot switch between direct input and external current
sensor input using the current input setting. Perform this setting in the normal measurement mode.
6 The line filter is always on. The line filter setting range is different than the setting range for normal
measurement. The line filter setting for high speed data capturing is not the same as the line filter
setting for normal measurement. The WT1800 saves both settings.
7 When the NULL feature is enabled, you cannot change the motor input signal type. Perform this
setting in the normal measurement mode.
8 You cannot select Auto. When the sampling frequency has been set to Auto for normal
measurement and you switch to high speed data capturing, the WT1800 operates under the Clock
C setting.
9 You can print a screen image. You cannot print numeric data lists.
10 During high speed data capturing, the setting for the NULL feature remains the same as the setting
specified during normal measurement (ON or OFF). You cannot change the setting for the NULL
feature. Perform this setting in the normal measurement mode.
Note
When the same setting is used for both normal measurement and high speed data capturing, that setting
cannot be specified when high speed data capturing has been started (Start).
IM WT1801-03EN

Appendix 10 Limitations on the Features during High Speed Data Capturing

Saving Setup Data
Saving Waveform Display Data
Saving Numeric Data
Saving a Screen Image
9
Printing
Automatic Printing
D/A Output
10
NULL Feature
Zero-Level Compensation
1
Operation
1, 2
Yes
No
No
2
2
Yes
2
Yes
No
No
No
3
Yes
1
4
5
6
App
Index
App-53

Advertisement

Table of Contents
loading

Table of Contents