YOKOGAWA WT1800 User Manual page 73

Precision power analyzer
Hide thumbs Also See for WT1800:
Table of Contents

Advertisement

4.1 Motor Torque Signal and Revolution Signal Input (TORQUE/SPEED; option)
Revolution Signal Input Connector (SPEED)
Apply a revolution sensor output signal—a DC voltage (analog) signal or pulse signal that is
proportional to the motor's rotating speed—that meets the following specifications.
DC Voltage (Analog input)
Item
Connector type
Input range
Effective input range
Input resistance
Maximum allowable input
Continuous maximum common-mode voltage
Pulse Input
Item
Connector type
Frequency range
Amplitude input range
Detection level
Pulse width
Input resistance
Continuous maximum common-mode voltage
Terminal Used for Analog Input
Apply analog input to terminal A.
Terminal Used for Pulse Input
• If you do not need to detect the revolution direction of a revolution signal (SPEED), apply pulse
input to terminal A.
• If you need to detect the revolution direction, apply phase A and phase B of a rotary encoder to
terminals A and B, respectively.
• If you need to measure the electrical angle, apply phase Z of a rotary encoder to terminal Z.
4-2
Specifications
Isolated BNC connector
1 V, 2 V, 5 V, 10 V, 20 V
0% to ±110% of the measurement range
Approx. 1 MΩ
±22 V
±42 Vpeak or less
Specifications
Isolated BNC connector
2 Hz to 1 MHz
±12 Vpeak
H level: approx. 2 V or more; L level: approx. 0.8 V or less
500 ns or more
Approx. 1 MΩ
±42 Vpeak or less
IM WT1801-03EN