When connecting the power supply, we recommend the cables specified in section Ordering
data (Page 109) (5 x 1.5 mm
If you want to assemble the cable yourself, then the conductor cross-section should be
1.5 mm
A cable cross-section of 2.5 mm² is mandatory for an amperage > 8 A.
Connecting push-pull cable connectors
Plug the push-pull cable connectors for 1L+/2L+ and RJ45 into the associated sockets (see
figure below). Ensure that the locking mechanism between the connector and socket is
properly applied. The connectors must engage.
Figure 4-5
Sealing unused sockets
Cover all unused push-pull sockets with caps in order to achieve degree of protection IP65,
IP66, or IP67. Refer to section
RF182C communication module
Operating Instructions, 10/2010
.
2
X01 24 V DC
Push-pull socket (with socket insert) for infeed of the 1L+ electronic/encoder
supply and the 2L+ load voltage supply
X02 24 V DC
Push-pull socket (with socket insert) for looping through of the 1L+
electronic/encoder supply and the 2L+ load voltage supply
X03 PN1
Push-pull socket for RJ45 for infeed from Ethernet
X04 PN2
Push-pull socket for RJ45 for loop-through from Ethernet
Connecting push-pull cable connectors
4.2 Wiring of the push-pull connection block
pre-assembled with push-pull connectors).
2
Ordering data
for order numbers.
Connecting
29