4.4 Wiring an RF182C to a controller with Ethernet connection

4.4
Wiring an RF182C to a controller with Ethernet connection
A connection from Ethernet to an M12 connection can be easily implemented.
Self-assembly of an Ethernet M12 cable
● You will need a pre-assembled PROFINET/Ethernet cable with M12 connectors at both
● You will need the following individual parts: Ethernet plug-in connector, M12 plug-in
Using a cabinet bushing Ethernet M12
This connection variant must always be used when the controller electronics is installed in a
cabinet. The following figure shows the connection layout.
PROFINET IO
Master module
SIMATIC S7
Figure 4-7
32
ends twice the required length. You will also need two Ethernet connectors for self-
assembly. Cut the M12 cable in the center and connect one Ethernet connector to each
free cable end. This will result in two Ethernet M12 cables.
connector, and PROFINET/Ethernet standard cable (unassembled). The parts can be
found in the ordering data. You can make up a cable to your own length requirements
using these parts.
Cabinet bushing
RF182C communication module
Operating Instructions, 10/2010