6.4.5

getTagStatus

The command requests different status information on a tag in the field.
Below the XML command for the tag status (getTagStatus) is described:
XML command
<command>
</command>
Note
Only with MOBY U
The italic XML tags <week> and <year> only apply for the MOBY U system. These italic tags
must be omitted for other MOBY systems!
XML response
Below the XML response without error entry (for error entries, see section Error messages
(Page 71)) is described:
<reply>
</reply>
Parameter
Parameter
Mode
Week
Year
Data
RF182C communication module
Operating Instructions, 10/2010
<getTagStatus>
<mode>Mode</mode>
<week>Week</week>
<year>Year</year>
</getTagStatus>
<resultCode>Errorcode</resultCode>
<getTagStatus>
<returnValue>
<data>Data</data>
</returnValue>
</getTagStatus>
Data type
ASCII hex
ASCII hex
ASCII hex
ASCII hex
6.4 Commands of the communication module
Values
00 = MOBY U
01 = RF300: Type and write protection status
02 = RF300: Diagnostic data
03 = RF300/MOBY D: Type and write protection status for
ISO tags
04 = RF600: Diagnostic data
00 ... FF (2 x ASCII)
00 ... FF (2 x ASCII)
0000 ... FFFF (ASCII string: max. 400 x ASCII)
Communication interface
57