Siemens RF182C Operating Instructions Manual page 77

Rfid systems
Table of Contents

Advertisement

Error code
Flashing of
ERR LED
3424
3425
3521
3523
3550
Note
Error handling procedure
If error messages occur, execute a reset command to eliminate the error.
If this procedure does not eliminate the error, disconnect the module from the power supply.
RF182C communication module
Operating Instructions, 10/2010
Description
-
Error when receiving the TCP channel
Connection was aborted
TCP/IP protocol error
Permissible number of connections at one port was exceeded
Check socket programming on the user side or find the fault with network analyzer
(Wireshark).
-
Receiving buffer overflow
Previous command is still active
Check if maximum possible number of commands was exceeded.
-
Incorrect UID
The length of the UID is not correct
A UID is required that has not been transferred by the user
Check UID
-
Conversion error
Check if individual characters of the user data of a command exceed the
permissible range for ASCII hex.
(Range 0 – 9 or A – F ). The number of characters must be an even number.
-
Error in the XML structure of a command message frame.
Check command structure
Error messages
9.3 Error messages of the RF182C
77