Self-Assembled Cable - Siemens RF182C Operating Instructions Manual

Rfid systems
Table of Contents

Advertisement

13.2

Self-assembled cable

A reader/SLG connector plug with screw terminals is provided for users who want to
individually pre-assemble their own cables (refer to the relevant system manual). Cables and
reader/SLG connector plugs can be ordered from the Catalog
Automation
Cable structure
You will need cables of the following specifications for self-assembled cables:
7 x 0.25 mm
LiYC11Y 7 x 0.25
Connectors
M12 connectors can be obtained from the relevant specialist dealers (e.g. Binder).
Pin assignment
The pin assignment is listed in the following table.
Table 13- 4
M12 connector (male)
RF182C communication module
Operating Instructions, 10/2010
.
2
Pin assignment
Connecting cable to the reader/SLG
13.2 Self-assembled cable
FS 10 Sensors for Production
Pin
Signal
Core color
1
1L+ (+ 24 V)
Note data sheet
provided by cable
2
−RxD
manufacturer
3
0 V
4
RxD
5
TxD
6
−TxD
7
Free
8
Functional
ground
(PE)/shield
107

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents