Setant - Siemens RF182C Operating Instructions Manual

Rfid systems
Table of Contents

Advertisement

Communication interface
6.4 Commands of the communication module
Tag status acknowledgement message frame
An acknowledgment message frame on the tag status is returned via the "Data" parameter.
Different acknowledgment message frames are returned depending on the set "mode". All
available acknowledgment message frames can be found in section Command and
acknowledgement telegrams (Page 111).
6.4.6

setAnt

Below the XML command for switching the antenna(s) on/off (setAnt) is described:
XML command
<command>
</command>
XML response
Below the XML response without error entry (for error entries, see section Error messages
(Page 71)) is described:
<reply>
</reply>
Parameter
Parameter
Mode
58
<setAnt>
<mode>Mode</mode>
</setAnt>
<resultCode>Errorcode</resultCode>
<setAnt/>
Data type
ASCII
Value
D/U/RF300:
01 = switch antenna on
02 = standby; switch antenna off
RF600:
00 = Antenna 1 off and Antenna 2 off
01 = Antenna 1 on and Antenna 2 off
02 = Antenna 1 off and Antenna 2 on
03 = Antenna 1 and 2 on
RF182C communication module
Operating Instructions, 10/2010

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents