Technical data

Table 11- 1
Ethernet interface to the user
Principle
Physical medium
Duty type
Transmission rate
Plug-in connection
Maximum cable length
Cable type
Autonegotiation
Autocrossing
Switch function
Serial interface to the reader/SLG
Connector
Max. cable length
Connectable readers/SLGs
Software functions
Tag/MDS addressing
Commands
Supply voltage
Rated value
Permissible range
Current consumption without
reader / SLG
Current consumption through reader
connection
Maximum infeed current in the
connection block M12, 7/8''
Maximum infeed current in the push-
pull connection block
Galvanic isolation
RF182C communication module
Operating Instructions, 10/2010
General technical data
1)
2)
Ethernet
Ethernet (TCP/IP communication)
10BASE-T Full or Half Duplex
100BASE-TX Fast Ethernet Full or Half Duplex
10/100 Mbit/s
M12, 4-pin, D coding
100 m
STP Cat 5
Yes
Yes
Yes, internal
2 x M12 coupler plugs, 8-pin
1000 m, dependent on Reader/SLG
(2 m = standard length; for other standard cables and self-
assembled cables, refer to Section
2x readers/SLG of the RFID families RF300, RF600,
MOBY D/U
Direct access via addresses
Initialize tag, read data from tag, write data to tag, etc.
24 V DC
20 V to 30 V DC
max. 500 mA; typ. 100 mA
Each 500 mA
1L = 6 A
2L = 8 A
Up to 40 °C:
1L = 12 A
3)
2L = 12 A
Yes
11
Connection cables
)
Up to 60 °C:
1L = 8 A
2L = 8 A