4.2

Wiring of the push-pull connection block

Features
● Connect the power supplies and Ethernet to the push-pull connection block:
● You can loop through the supply voltages and Ethernet via the second push-pull
Requirements
● Wire the push-pull connection block with the supply voltage switched off.
Required tools
● Screwdriver
● Stripping tool for wiring the push-pull cable connector if you assemble your own cables.
Accessories required
● Pre-fabricated cables with push-pull cable connector for 1L+/2L+ and RJ45. The cables
● If you assemble your own cables:
RF182C communication module
Operating Instructions, 10/2010
– Push-pull connection (RJ45), D-coded: Ethernet
– Push-pull connection: Supply voltages
connection.
are available in various lengths from appropriate manufacturers.
– 5-core cable and push-pull cable connector for 1L+/2L+
– 4-core, shielded cable (bus cable) and push-pull cable connector for RJ45
Note
Refer to the manufacturer's documentation if you are fabricating the cables with the
push-pull cable connectors.
4.2 Wiring of the push-pull connection block
Connecting
27