Panasonic CS-VZ9SKE Service Manual page 95

Hide thumbs Also See for CS-VZ9SKE:
Table of Contents

Advertisement

4
OPERATION MODE
The total of cumulative operation time of heating, cooling, defrosting, automatic, blower operation that is
being recorded in EEPROM will be notified by number of times of timer LED flash and notification sound.
Cumulative operation time
Less than 3 mins
3 ~ 15 mins
15 ~ 30 mins
30 mins ~ 1hrs 30mins
1hrs 30mins ~ 2hrs 30mins
2hrs 30 mins and over
EEP memory timing of cumulative operation time of operation modes is changed according to total of
cumulative operation time.
Total of cumulative operation time
Less than 3 minute
Less than 15 minute
Less than 30 minute
30 minute and over
5
PREFERENCE SETTING MODE
Set mode type
Remote control No. switch/
execution check mode
Diagnosis code received
"Beep"
Electric current switch mode
Diagnosis code received
"Two Beep"
Not used
Diagnosis code received
"Three Beep"
Not used
Diagnosis code received
"Four Beep"
Not used
Diagnosis code received
"Bleep"
Each mode is cancelled if no operation is performed for 5 minutes or any code other than the
diagnosis code is received from the remote control.
Number of times of LED flash
and notification sound
1
2
3
4
5
6
EEP memory timing
Continuous operation for 3 minute and stop operation
Continuous operation for 15 minute and stop operation
Continuous operation for 30 minute and stop operation
Stop ⇒ The first time of starting operation : continuous operation for 30 minute and stop operation
More than those above : Continuous operation with 1 hour and stop operation
Remote control switch
Set remote control No.
Set electric current Hi
95
Notification sound
No failure memory
bleep
"Beep"
Emergency SW
Execution check mode
Power relay ON
"Beep"
"Beep"
Emergency SW
Set electric current Lo
"Beep"
Existence of failure memory
bleep bleep

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-vz9skeCu-vz12skeCs-vz12ske

Table of Contents